Some Lennox error codes

There are 2 LEDs.
LED#1                                       LED#2

Simultaneous slow flash             Simultaneous slow flash             Normal operation

Simultaneous fast flash              Simultaneous fast flash              Normal call for heat

Slow flash                                 On                                           Limit open

Off                                          Slow flash                                  Pressure switch problem

Alternating slow flash                Alternating slow flash                  Flame failure

Slow flash                                Off                                            Flame sensed without gas valve on

On                                          Slow flash                                  Flame rollout switch open

On, on, off                              On, off, on                                  IFC failure or wiring problem

Fast flash                               Slow flash                                   Power polarity reversed

Slow flash                              Fast flash                                    Low flame signal

Alternating fast flash              Alternating fast flash                    Low voltage or broken ignitor